title: "Notifications sent despite downtime"
description: "Notifications are sent for checks despite downtime being set and visible in the UI due to a mismatch between the database and collector datastore states. Running the recreatedowntime script restores downtime in the collector datastores to suppress notifications properly."
url: "https://docs.itrsgroup.com/docs/faq/opsview/4922721319837-opsview-notifications-sent-despite-downtime/index.html"
---
## Symptoms

- Downtime is set on a check and this downtime is visible in the UI
- Downtime exists for the check in the `` runtime.nagios_scheduleddowntime` `` database table
- Notifications are sent for the check despite the above

### Cause: disparity in downtime state between the database and datastore

When downtime is scheduled for a check or host, it is set in two places: `runtime.nagios_scheduleddowntime` and the datastore of the collector(s) monitoring the host.

Downtime displayed in the UI comes from the `runtime.nagios_scheduleddowntime` table. However, downtime stored in the collector datastore is what actually suppresses notifications.

If the datastore on the collector(s) monitoring the host is reinstalled or otherwise corrupted, the downtime is ‘forgotten’ by the collector so is not enforced.

Collector datastore corruption can happen when collectors are redeployed to different clusters.

### Solution: `recreate_downtime`

Using the `recreate_downtime` support script, downtime stored in the database can be recreated in the datastores of collectors.

See our page on using the `recreate_downtime` script.