## **PROBLEM:** GUI is throwing out an error causing a Lock-up. OP5 - GUI is throwing out an error even though my license is still valid **Checking the validity of the license:**

### You can see that the license is still valid: asmonitor /opt/plugins/check\_op5\_license -T d -w 30 -c 15 0 year(s) 2 month(s) 29 day(s) left|'left'=90;@30;@15

### P.S For other process of looking into the license validity: [OP5 Monitor - How can I see what my ITRS OP5 Monitor License contains or how long it is valid? – Support - ITRS Group](https://docs.itrsgroup.com/docs/faq/op5/360022938294-op5-monitor-how-can-i-see-what-my-itrs-op5-monitor-license-contains-or-how-long-it-is-valid/index.html)

## **SOLUTION:**

Restart php-fpm service.

`# systemctl restart php-fpm`

This would fix the issue in most cases. If problem persists, contact ITRS support. A new license file may be needed.