title: "NetProbe - How to configure Perfmon plugin when you are seeing a blank dataview"
description: "Configuring the Perfmon plugin to monitor SynchronizationNuma counters may show a blank dataview due to required text string values. The workaround is to use the text names for objectID and counterID instead of their numeric IDs."
url: "https://docs.itrsgroup.com/docs/faq/geneos/360019023634-geneos-netprobe-how-to-configure-perfmon-plugin-when-you-are-seeing-a-blank-dataview/index.html"
---
I am trying to monitor the following perfmon object: `(7054) SynchronizationNuma`

Counters that the `SynchronizationNuma` object defines:

- `(7138) Exec. Resource Boost Shared Owners/sec`
- `(7136) Exec. Resource Boost Excl. Owner/sec`
- `(7134) Exec. Resource Set Owner Pointer Shared (Existing Owner)/sec`

![SynchronizationNuma counters](https://docscdn.itrsgroup.com/faq/images/geneos/counters-SynchronizationNuma.PNG)

![Perf_Synchronization dataview](https://docscdn.itrsgroup.com/faq/images/geneos/Perf_Synchronization-dataview.PNG)

The problem is that there are some objects that require text string values for `objectID` and `counterID`. This is considered a bug, but as a workaround, you have to insert the text `SynchronizationNuma` instead of its object id of `7054`. And you have to insert the text `Exec. Resource Boost Shared Owners/sec` instead of its counter id of `7138`.

![Counter values for Synchronization](https://docscdn.itrsgroup.com/faq/images/geneos/synchronization-values.png)

Result: