## Problem

Error encountered:
ERROR: HARDWARE PdhEnumObjectItems() failed with code 0xc0000bb8

Sampling status:

![Geneos - Windows Netprobe - ERROR: HARDWARE PdhEnumObjectItems() failed with code](https://docscdn.itrsgroup.com/faq/images/geneos/14622948182941-inline-1-image001.png)

### Possible cause

*This log is associated with errors and problems with the Performance (Perfmon) counters on the Windows server. There is a known bug where the hardware plugin stops working with the error: Cannot access CPU Performance Data. Please check if user privileges are sufficient when adding a specific Perfmon sampler. for version 6.9.0*

### Possible solution(s)

This bug was fixed in version **7.4.0**, upgrading should help resolve the issue.

**Other workarounds:**

1. Disable the Hardware sampler and Perfmon sampler.
2. Save the configuration.
3. Restart the NetProbe service.
4. Re-enable the Hardware sampler and Perfmon sampler.
Note: The workaround above restores functionality, but only until the NetProbe is restarted again.

## Related article(s)