If the `var\_ref` value exceeds 2,147,483,647 then we get back a negative value rather than the large unsigned int stored in the database.

If the `REF` value in the `var\_ref\_` table exceeds 2,147,483,647 in value, then the `var\_ref` values that will be stored in user tables will be negative.

For example:

```
select ref from var\_ref\_table WHERE varname ='%toolkit2.2.value' and  tablename='os\_table'
```

The resulting `var\_ref` value will be 2,305,291,474. But in the Gateway, the resulting `REF` value is already translated into a negative value:

```
DEBUG: Schema1\_0::executePreparedQueryReturnLong QUERY=[SELECT ref FROM var\_ref\_table WHERE varname = :varname AND tablename = :tablename] DATA=[ :varname='*%toolkit2.2.value*' :tablename='os\_table' ]

DEBUG: Schema1\_0::executePreparedQueryReturnLong Returning**-1989675822**
```


**Note**



The value for the var\_ref column is determined by auto-incrementing positive integer, databases should implement this as the largest value + 1.




MySQL:

```
CREATE TABLE `node\_ref\_table` (* *`ref` int(11) NOT NULL auto\_increment,*
```

A 4 byte positive integer displayed to 11 characters when selected.

SQL Server or Sybase:

```
CREATE TABLE var\_ref\_table (ref numeric(10,0) identity, ...
```

Positive integer to 10 digits of precision. `identity` is the auto-increment type.

Oracle:

```
CREATE TABLE var\_ref\_table (REF NUMERIC(10,0) ...

CREATE SEQUENCE var\_ref\_seq START WITH 1 INCREMENT BY 1 NOMAXVALUE; CREATE TRIGGER var\_ref\_trigger BEFORE INSERT ON var\_ref\_table FOR EACH ROW BEGIN SELECT var\_ref\_seq.nextval INTO :new.REF FROM dual;END;
```

As before but a trigger is used to auto-increment the value. The gateway should be able to detect the error conditions since version GA4.2.