title: "What does the Netprobe log entry \"ERROR: ActionManager Failed lookup for SamplerManagerPeer for probe \u003cNetprobe Name\u003e - remote action \u003cAction Name\u003e failed to fire\" mean"
description: "The Netprobe log entry indicates a failed attempt to execute an Action on a remote Netprobe's imported dataview. This error occurs because actions cannot run on imported dataviews unless the Netprobe is on the Gateway server."
url: "https://docs.itrsgroup.com/docs/faq/geneos/115004030989-geneos-what-does-the-netprobe-log-entry-error-actionmanager-failed-lookup-for-samplermanagerpeer-for-probe-netprobe-name-remote-action-action-name-failed-to-fire-mean/index.html"
---
## Missing Netprobe

This means that the an attempt to execute an Action failed as it was attempted against a remote NetProbe's Imported dataview.

Sample log entry:

```
ERROR: ActionManager Failed lookup for SamplerManagerPeer for probe 'NP64 LAWIN 6370' - remote action 'Print target value to a file' failed to fire
```

## Additional information

This happens given the following conditions:

1. Create a Rule that targets an imported data item
2. The Rule's Action has its run location set to the Netprobe
3. The NetProbe is not running on a Gateway server

As the error is reported against an Imported NetProbe it will never be able to execute an action unless the actual netprobe is on the Gateway server so in general a rule should not be configured against an imported dataview to call a remote action.