title: "How to fix \"Could not load remote setup for gateway\" error when opening Gateway Setup editor"
description: "The \"Could not load remote setup for gateway\" error occurs when opening the Gateway Setup editor in Geneos. To fix it, stop the gateway process, delete the gateway and editor cache folders, then restart the gateway and console."
url: "https://docs.itrsgroup.com/docs/faq/geneos/115004030689-geneos-how-to-fix-could-not-load-remote-setup-for-gateway-error-when-opening-gateway-setup-editor/index.html"
---
**To resolve this issue, follow the steps provided below:**

- Identify the problematic gateway process, you can use the `ps` command to list running processes.

e.g. `ps -ef

grep gateway`.  In this example, let's say that the problematic gateway has a process ID of 1341. **Highlighted in yellow**  **Geneos -  How to fix "Could not load remote setup for gateway" error when opening Gateway Setup editor**

- Stop the gateway process. Use the `kill` command to terminate the gateway process.

e.g. `kill 1341`

Geneos -  How to fix "Could not load remote setup for gateway" error when opening Gateway Setup editor

- Delete the cache folder in the gateway's working directory.

Use the `rm` command to remove the entire cache directory or specific files.  e.g. `rm -rf <path>`

**Note:** Be cautious as deleting the wrong files could affect Geneos functionality. **rm -rf** is a command that is used to **remove files and directories recursively and forcefully**.

Geneos -  How to fix "Could not load remote setup for gateway" error when opening Gateway Setup editor

- Start the gateway up again and test

e.g. `./start_gateway`

**If this does not resolve the issue, there are additional steps:**

- Exit the Active Console - Bring up File Explorer and change directory into: %AppData%\GatewaySetupEditor (You may do this by pressing Windows + R and run %AppData%\GatewaySetupEditor)

Geneos -  How to fix "Could not load remote setup for gateway" error when opening Gateway Setup editor

- Remove the cache subdirectory - Restart your console, connect to the gateway, and try to edit it again

**Note:** Once deleted, the data cannot be recovered. Please proceed with caution.