title: "Active Console - Gateways disconnect when the console starts up"
description: "Gateways disconnect when the Active Console starts due to overload from simultaneous connections. Solutions include refactoring List Views and adding the -queueConnections flag to connect Gateways sequentially."
url: "https://docs.itrsgroup.com/docs/faq/geneos/115004029129-geneos-active-console-gateways-disconnect-when-the-console-starts-up/index.html"
---
## Related to

*Gateways disconnect when the console starts up, Gateway Disconnect, Active Console*

## Connecting to Gateways

The Active Console connects to all Gateways simultaneously. [This event gives a significant load to the Active Console because it processes the XPaths or data items from those Gateways](https://docs.itrsgroup.com/docs/faq/geneos/115004022745-geneos-managing-load-in-geneos/index.html). When the console is overloaded, it either stops or slows down the processing of data items. This, in turn, triggers the other Gateways' [heartbeat timeout (75 seconds)](https://docs.itrsgroup.com/docs/geneos/current/processing/configuration/gateway_probes/index.html#probes--probe--heartbeatinterval) and disconnects the Active Console.

### Solution

There are several ways to solve the said disconnections:

## Solution 1

Remove or refactor the List Views that contain non-identifying predicates. [The detailed steps can be seen in this FAQ](https://docs.itrsgroup.com/docs/faq/geneos/4409014541073-geneos-active-console-refactor-list-views-containing-xpaths-with-non-identifying-predicates/index.html).

## Solution 2

If the above does not work, then add the **-queueConnections** flag to the ActiveConsole.gci file. This instructs the Active Console to connect to the Gateways one by one. Here are the steps:

1. Shut down the Active Console.
2. Open the ActiveConsole.gci file using a text editor. The file is located in the same folder as the ActiveConsole.exe file.

   ![Geneos - Active Console - Gateways disconnect when the console starts up](https://docscdn.itrsgroup.com/faq/images/geneos/115004029129-34451105128349-mceclip0.png)

3. Add the **-queueConnections** flag at the end of the file. Make sure that there are no leading or trailing spaces.

   ![Geneos - Active Console - Gateways disconnect when the console starts up](https://docscdn.itrsgroup.com/faq/images/geneos/115004029129-34451129474205-mceclip1.png)

4. Save the changes.
5. Start the Active Console.

## Reference

- [Managing Load in Active Console](https://docs.itrsgroup.com/docs/faq/geneos/115004022745-geneos-managing-load-in-geneos/index.html)
- [Refactor List Views that contain non-identifying predicates](https://docs.itrsgroup.com/docs/faq/geneos/4409014541073-geneos-active-console-refactor-list-views-containing-xpaths-with-non-identifying-predicates/index.html)