## Start of day

The error appears when configuring an active time that has an [endTime](https://docs.itrsgroup.com/docs/geneos/current/processing/monitoring-and-alerts/gateway_active_times/index.html#activeTimes_activeTime_schedulePeriod_endTime) setting value of **00:00:00** because the said value means *start of day*:

![Active time start of day](https://docscdn.itrsgroup.com/faq/images/geneos/115004023625-inline-1-active_time_start_of_day.png)

## Active time that spans through midnight

The said error usually happens when configuring an active time that spans through midnight. This configuration can be achieved by disabling the *endTime* setting of the first *schedulePeriod* entry. When the said setting is disabled, the active time treats this as *end of day*:

![Active time end of day](https://docscdn.itrsgroup.com/faq/images/geneos/115004023625-inline-2-active_time_end_of_day.png)