Collection Agent 7.x Release Notes
Overview Copied
This page provides information about the Collection Agent version 7.x release, including new features and resolved issues.
For a detailed overview of the Geneos 7.x.x release, including key highlights for other components, see Geneos 7.x Release Notes.
Collection Agent 7.0.0 Copied
Released: 01 November 2026 Standalone release
New features and enhancements Copied
These are the new features and enhancements of this release:
| Issue key | Release description |
|---|---|
| HP-3958 | Removed the downsampled metric data point from the collection data model. The platform API downsampled metric type remains available. |
| HP-4165 | The Collection Agent now starts collectors only after the workflows and all reporters are ready. It updates its health status when a collector, reporter, or self-monitoring status changes. A reporter that has not started, or that responds slowly, no longer causes the agent to fail a health check. |
Issues fixed Copied
These are the issues we have fixed in this release:
| Issue key | Release description |
|---|---|
| HP-4176 | Fixed an issue where one reporting failure left the Collection Agent unhealthy until it was restarted. The Collection Agent now recovers when delivery succeeds, drops a data point that cannot be delivered, and waits longer between retries, with random variation. |
| HP-4245 | Fixed an issue where a pass-through pipeline retried some failed deliveries and reported others as permanent. Each data point is now reported once, and a temporary failure is returned to the sender. |
| HP-4258 | Fixed an issue where the Collection Agent could start a component during shutdown. |
| HP-4348 | Fixed an issue where sending events to Kafka one record at a time slowed delivery to about 10 records a second. Each group of records is now sent together, so a backlog can clear. |
| HP-4380 | Fixed an issue where the Collection Agent waited for the self-monitoring interval before it reported ready. It now reports ready as soon as its components are ready. |
Disclaimer
The information contained in this document is for general information and guidance on our products, services, and other matters. It is only for information purposes and is not intended as advice which should be relied upon. We try to ensure that the content of this document is accurate and up-to-date, but this cannot be guaranteed. Changes may be made to our products, services, and other matters which are not noted or recorded herein. All liability for loss and damage arising from reliance on this document is excluded (except where death or personal injury arises from our negligence or loss or damage arises from any fraud on our part).